Title CIED Connectivity Status Value Set
Experimental False
Realm uv
Authority hl7
Description The overall system connectivity status as calculated by the CIED manufacturer

Resources that use this resource

StructureDefinition
cied-connectivity-status Observation - CIED Connectivity

Resources that this resource uses

CodeSystem
cied-connectivity CIED Connectivity Status Values


Narrative

Note: links and images are rebased to the (stated) source

Generated Narrative: ValueSet cied-connectivity-state-vs

  • Include these codes as defined in http://hl7.org/fhir/uv/cardx-cied/CodeSystem/cied-connectivity
    CodeDisplayDefinition
    not-applicableConnectivity states are not applicable for this device. E.g. device is not compatible with remote monitoring or requires patient initiated interrogationsConnectivity states are not applicable for this device. E.g. device is not compatible with remote monitoring or requires patient initiated interrogations
    connectedCommunication has been successful within the expected time period.Communication has been successful within the expected time period.
    disconnectedCommunication has not occurred within the expected time period.Communication has not occurred within the expected time period.

Source

{
  "resourceType" : "ValueSet",
  "id" : "cied-connectivity-state-vs",
  "text" : {
    "status" : "extensions",
    "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p class=\"res-header-id\"><b>Generated Narrative: ValueSet cied-connectivity-state-vs</b></p><a name=\"cied-connectivity-state-vs\"> </a><a name=\"hccied-connectivity-state-vs\"> </a><a name=\"cied-connectivity-state-vs-en-US\"> </a><ul><li>Include these codes as defined in <a href=\"CodeSystem-cied-connectivity.html\"><code>http://hl7.org/fhir/uv/cardx-cied/CodeSystem/cied-connectivity</code></a><table class=\"none\"><tr><td style=\"white-space:nowrap\"><b>Code</b></td><td><b>Display</b></td><td><b>Definition</b></td></tr><tr><td><a href=\"CodeSystem-cied-connectivity.html#cied-connectivity-not-applicable\">not-applicable</a></td><td>Connectivity states are not applicable for this device. E.g. device is not compatible with remote monitoring or requires patient initiated interrogations</td><td>Connectivity states are not applicable for this device. E.g. device is not compatible with remote monitoring or requires patient initiated interrogations</td></tr><tr><td><a href=\"CodeSystem-cied-connectivity.html#cied-connectivity-connected\">connected</a></td><td>Communication has been successful within the expected time period.</td><td>Communication has been successful within the expected time period.</td></tr><tr><td><a href=\"CodeSystem-cied-connectivity.html#cied-connectivity-disconnected\">disconnected</a></td><td>Communication has not occurred within the expected time period.</td><td>Communication has not occurred within the expected time period.</td></tr></table></li></ul></div>"
  },
  "url" : "http://hl7.org/fhir/uv/cardx-cied/ValueSet/cied-connectivity-state-vs",
  "version" : "0.1.0",
  "name" : "cied-connectivity-state",
  "title" : "CIED Connectivity Status Value Set",
  "status" : "draft",
  "experimental" : false,
  "date" : "2025-05-15T00:37:06+00:00",
  "publisher" : "HL7 International / Clinical Interoperability Council",
  "contact" : [
    {
      "name" : "HL7 International / Clinical Interoperability Council",
      "telecom" : [
        {
          "system" : "url",
          "value" : "http://www.hl7.org/Special/committees/cic"
        },
        {
          "system" : "email",
          "value" : "ciclist@lists.hl7.org"
        }
      ]
    }
  ],
  "description" : "The overall system connectivity status as calculated by the CIED manufacturer",
  "jurisdiction" : [
    {
      "coding" : [
        {
          "system" : "http://unstats.un.org/unsd/methods/m49/m49.htm",
          "code" : "001",
          "display" : "World"
        }
      ]
    }
  ],
  "compose" : {
    "include" : [
      {
        "system" : "http://hl7.org/fhir/uv/cardx-cied/CodeSystem/cied-connectivity",
        "concept" : [
          {
            "code" : "not-applicable",
            "display" : "Connectivity states are not applicable for this device. E.g. device is not compatible with remote monitoring or requires patient initiated interrogations"
          },
          {
            "code" : "connected",
            "display" : "Communication has been successful within the expected time period."
          },
          {
            "code" : "disconnected",
            "display" : "Communication has not occurred within the expected time period."
          }
        ]
      }
    ]
  }
}